Reinforcement for the Victor Fouche former maternity hospital, Martinique
The earthquake resistance work carried out for the building housing the Victor Fouche former maternity hospital, enabled certain reinforcement techniques to be developed such as “nailing” existing foundations by using micropiles, reinforcing hollow body concrete floors by means of pre-stressing and post-tensioning or the development of reinforced concrete retaining walls at variable thicknesses and dimensions depending on the intensity of the seismic stresses to be borne. Studies were carried out with Professor Victor Davidovici (Dynamique Concept).
Type
Seismic reinforcement, Sustainability
Materials and construction systems
Concrete and prestressed concrete, Steel frame
Location
France, Fort de France, Martinique (FR-97)
Assignment
Diagnosis, Feasibility, Structural engineering project design, Working drawings
Architect
Olivier Compère
Customer
Conseil General de Martinique
Associate Engineering Offices
Dynamique Concept Victor Davidovici / Fondetud
Price
7 M€
Photos credit
Dynamique Concept, C&E
Work completion date
2016